Basic Info.

Origin
China
Production Capacity
500 PCS/Year

Product Description

1. System overview
This system is usually used as an independent subsystem of BAS (Building Equipment Management System) in the three major systems of intelligent buildings. The system uses the parameter changes of various detection devices (smoke detectors and temperature detectors) in the fire protection system to carry out fire alarms, and realizes the linkage control of fire protection through relevant signals. The system can perform various simulated fire and alarm linkage operation demonstrations, system settings, linkage programming, circuit design, networking, circuit and setting fault judgment and troubleshooting, etc.

2. Product features
1. The training devices are connected by terminal blocks, which can form different fire protection circuits according to the training content;
2. The training device has a fire display and linkage function commonly used in engineering;
3. The system adopts a bus structure.

Three, technical parameters
1. Working power supply of training platform: AC220V±10% 50Hz
2. Working environment: the ambient temperature range is -20ºC~+45ºC, relative humidity <85%
3. Dimensions: 1668mm×805mm×1484mm

4. Training content
1. System equipment recognition and wiring operation
2. Installation and connection of alarm controller, short-circuit isolator and linkage interface module
3. Installation, connection and use of fire display panel
4. Installation and connection of various fire detectors
5. Installation and connection of intelligent input and output modules, sound and light alarms, and alarm buttons
6. Component address coding settings
7. System management operation
8. System data query operation
9. Equipment start and stop operation
10. Single point operation
11. Linkage programming
12. Judgment and treatment of line faults
13. Judgment and correction of program setting errors
14. Design and install a simple application system

Five, basic configuration
1. Power control panel (iron double-layer matte dense pattern spray structure)
Provide AC power: single-phase AC 220V 50Hz, with overcurrent protection
2. Building training table
The training table is made of iron double-layer matt dense pattern sprayed structure, the table top is fireproof, waterproof, wear-resistant high-density board, the structure is sturdy, the shape is like a rectangular closed structure, the shape is beautiful and generous; there are two large drawers and cabinets The door is used to place tools, store pendants and materials, etc. The desktop is used to install the power control panel and provide a spacious and comfortable work surface. The training table is also equipped with four universal wheels and four fixed adjustment mechanisms, which are easy to move and fix, which is conducive to the layout of the training room.
3. Fire alarm controller (linkage type)
(1) LCD screen specifications: 240×160 dots, 150 Chinese characters can be displayed on the same screen
(2) The maximum capacity is 242 address code points
(3) 64 fire display panels can be connected externally;
(4) 30 direct manual operation bus control points
(5) Configure 6 direct control points
(6) Two-bus connection with non-polar signal is adopted between the controller and the detector
(7) The direct control point and the field equipment adopt two-wire polarized connection, and the maximum connecting wire length should not exceed 1000m.
4. Fire display panel
The fire display panel is networked with the fire alarm controller through RS485 communication or bus, and displays various event information on the floor in real time, so that the staff on the floor can understand the fire event on the floor in a timely and accurate manner, and take corresponding measures quickly.
5. Detector
It is equipped with three types of detectors: combustible gas detector, smart photoelectric smoke detector and differential fixed temperature fire detector.
6. Input module, control module
The input module is mainly used to detect signals such as pressure switches, and the control module is mainly used to control equipment such as smoke exhaust valves, air supply valves, and rolling doors.
7. On-site interface of linkage panel
(1) Three-wire control, simple and convenient wiring part, easy to realize the start-stop answer function;
(2) Two output control methods are available, level output and pulse output.
8. Manual alarm button
When a fire occurs, press the plexiglass sheet, the fire alarm light of the button will light up, and a fire alarm signal will be sent to the controller at the same time;
9. Fire hydrant button
In case of fire, press the tablet pressing controller to alarm, light up the fire alarm indicator (red), and output a set of external control empty contacts. When the fire pump is started, the pump start answer signal is connected, and the pump start indicator lights (green), When resetting, slide down the sliding cover and press the reset button.
10. Sound and light alarm, alarm bell
After receiving the control signal when a fire occurs at the scene, a strong audible alarm signal will be issued to remind the people on the scene to pay attention.
11. Electronic encoder
Complete functions such as coding, device type and sensitivity change of field devices.

6. Basic configuration
Number Name Specification QTY Unit Note
1 Fire alarm controller GST-200 1 set  
2 Point type smoke detector JTY-GD-G3 1 pcs  
3 Point type heat detector JTW-ZCD-G3N 1 pcs  
4 Detector universal base DZ-02 2 pcs  
5 manual alarm button J-SAM-GST9122 1 pcs  
6 Fire hydrant alarm button J-SAM-GST9123A 1 pcs  
7 Audible alarm HX-100B 1 pcs  
8 Isolation module GST-LD-8313 1 pcs  
9 Single input module GST-LD-8300 1 pcs  
10 Single input output module GST-LD-8301 1 pcs  
11 Electronic encoder GST-BMQ-2 1 pcs  
12 Fire display ZF-101 1 pcs  
13 Training table customize 1 set  


Fire Alarm System Training System Education EquipmentFire Alarm System Training System Education EquipmentFire Alarm System Training System Education EquipmentFire Alarm System Training System Education EquipmentFire Alarm System Training System Education EquipmentFire Alarm System Training System Education EquipmentFire Alarm System Training System Education Equipment